Functional outcomes used to compare single radius and multiradius of curvature designs in total knee arthroplasty.

Cook, Laurence E; Klika, Alison K; Szubski, Caleb R; Rosneck, James; Molloy, Robert; Barsoum, Wael K · J Knee Surg · 2012

retrospective_cohort · Level III

Where this comes from

Abstract

A recent development to better recreate joint kinematics has been a change from a multiradius (MR) design to a single radius (SR) design. We analyzed 559 primary total knee arthroplasty (TKA) procedures which used either a SR (n = 426 Triathlon; Stryker Orthopaedics, Mahwah, NJ) or MR of curvature knee system (n = 133 Duracon; Stryker Orthopaedics, Mahwah, NJ) (79.3% follow-up; 705 total TKA procedures identified). Patients were administered a modification of the Knee Society score (KSS) (3.9 years average follow-up). The SR design showed improvements over the MR design in pain (p = 0.021), stability (p = 0.002), flexion (p = 0.006), ability to completely straighten the knee (p = 0.025), stair climbing (p = 0.0001), walking (p = 0.0001), use of assistive devices (p = 0.0005), postoperative knee score (p = 0.0005), and postoperative function (p < 0.0001). Analysis of the change in KSS knee (p = 0.002) and function scores (p = 0.002) from preoperative visit to postoperative follow-up favored the SR design as well. These data support the use of SR implants and provide evidence of improved outcomes in terms of function, stability, and pain.

Medical subject headings

Anatomy