The 2012 John Charnley Award: Clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 23070661.
- Also identified by DOI 10.1007/s11999-012-2604-0 and PMC identifier 3549171.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Highly crosslinked polyethylene (HXLPE) in THA was developed to reduce particle-induced periprosthetic osteolysis. A series of clinical studies were initiated to determine the clinical efficacy as judged by patient-reported scores, radiographic osteolysis, and wear analysis of one form of HXLPE. The purposes of this series of studies were to (1) determine the wear rates of one form of HXLPE; (2) report long-term (7-10 years) patient-reported outcome measures; (3) assess the effect of femoral head size on wear; and (4) determine the incidence of periprosthetic osteolysis. A single-center and two multicenter studies were conducted on 768 primary patients (head size 26-36 mm) undergoing THA at eight medical centers. Patient-reported outcome scores, radiographic grading for osteolysis, and radiographic wear evaluation were performed. Serial plain radiographs showed no periprosthetic osteolysis in the three studies. The average femoral head penetration rates did not correlate with time in vivo for patients with standard femoral head sizes. Although there was an indication of higher wear in patients with 36-mm diameter femoral heads, it was below the threshold for producing osteolysis. The introduction of this HXLPE substantially improved the prognosis of patients after THA up to 13 years as judged by clinical scores, incidence of osteolysis, and polyethylene wear measurements. Level III, therapeutic study. See the Guideline for Authors for a complete description of levels of evidence.
Medical subject headings
- Awards and Prizes
- Femur Head
- Hip Joint
- Hip Prosthesis
- Osteolysis
- Polyethylenes
- Prosthesis Failure
Anatomy
- femur