To compare a novel neonatal resuscitation cart (NRC) to a generic code cart (GCC). A prospective, randomised, controlled, crossover trial was performed to compare the utility of the NRC with the GCC during simulated deliveries of extremely low birthweight infants and infants with gastroschisis. Fifteen subjects participated. Mean times and accuracy of equipment and supply retrieval were compared for each scenario using the Wilcoxon test. Mean acquisition times for the NRC were always faster (by 58% to 74%) regardless of scenario (p<0.01). Accuracy of equipment selection did not differ. Ease of use was judged using a Likert scale (1=easiest to use; 5=most difficult), with mean score for NRC 1.1 and GCC 3.7 (p<0.0001). All subjects rated the NRC as easier to use. The NRC was superior to the GCC in acquisition speed, supply selection and ease of use.