Test performance characteristics of Anti-HEV IgG assays strongly influence hepatitis E seroprevalence estimates.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 23148290.
- Also identified by DOI 10.1093/infdis/jis688.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Hepatitis E virus (HEV) seroprevalences of 0.3%-53% were reported from industrialized countries. Because these estimates may be influenced by detection assays, this study compares 3 frequently used tests for HEV detection: the MP Diagnostics HEV immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA), the Axiom Diagnostics HEV IgG enzyme immunoassay (EIA), and the Mikrogen recomLine HEV IgG assay. Sera from 200 healthy healthcare workers and 30 individuals with acute HEV infection were analyzed. Among the healthy individuals, HEV IgG was found in 4.5% by the MP Diagnostics assay, in 29.5% by the Axiom Diagnostics assay, and in 18% by the Mikrogen assay. Among individuals with acute HEV infection, positive results were obtained for 83.3%, 100%, and 96.7%, respectively. Thus, the 3 assays show clear differences in diagnostic sensitivity.
Medical subject headings
- Enzyme-Linked Immunosorbent Assay
- Hepatitis Antibodies
- Hepatitis E
- Hepatitis E virus
- Immunoglobulin G