Millisecond spatiotemporal dynamics of FRET biosensors by the pair correlation function and the phasor approach to FLIM.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 23248275.
- Also identified by DOI 10.1073/pnas.1211882110 and PMC identifier 3538204.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Here we present a fluctuation-based approach to biosensor Förster resonance energy transfer (FRET) detection that can measure the molecular flow and signaling activity of proteins in live cells. By simultaneous use of the phasor approach to fluorescence lifetime imaging microscopy (FLIM) and cross-pair correlation function (pCF) analysis along a line scanned in milliseconds, we detect the spatial localization of Rho GTPase activity (biosensor FRET signal) as well as the diffusive route adopted by this active population. In particular we find, for Rac1 and RhoA, distinct gradients of activation (FLIM-FRET) and a molecular flow pattern (pCF analysis) that explains the observed polarized GTPase activity. This multiplexed approach to biosensor FRET detection serves as a unique tool for dissection of the mechanism(s) by which key signaling proteins are spatially and temporally coordinated.
Medical subject headings
- Biosensing Techniques
- Fluorescence Resonance Energy Transfer
- Microscopy, Fluorescence
- Proteins
- Signal Transduction
- rho GTP-Binding Proteins