Antegrade interlocking nailing versus dynamic compression plating for humeral shaft fractures.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 23255631.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To compare antegrade interlocking nailing with dynamic compression plating for humeral shaft fractures in terms of functional outcomes, union and complication rates. 34 men and 22 women aged >18 years with fresh humeral shaft fractures (up to grade IIIa) with or without neurological deficits underwent either antegrade interlocking nailing (n=31) or dynamic compression plating (n=25). Functional outcome of the upper limbs (according to the American Shoulder and Elbow Surgeons [ASES] score), pain, rates of union, and complications in the 2 groups were compared. Respectively in the nailing and plating groups, mean operating times were 65 and 112 minutes (p<0.001), mean blood loss volumes were 20 and 232 ml (p<0.001), mean ASES scores were 31.4 and 29.0 (p=0.448), complication rates were 20% (6/31) and 24% (6/25) [p=0.900], non-union rates were 13% (4/31) and 8% (2/25) [p=0.625], and delayed union rates were 7% (2/31) and 4% (1/25) [p=0.787]. Both techniques were appropriate for treating humeral shaft fractures.
Medical subject headings
- Fracture Fixation, Internal
- Humeral Fractures
Anatomy
- humerus