Custom intramedullary intercalating device for treatment of supracondylar fracture between constrained total knee arthroplasty and well-fixed total hip arthroplasty.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 23266136.
- Also identified by DOI 10.1016/j.knee.2012.11.007.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Management of periprosthetic fractures between ipsilateral total knee arthroplasty (TKA) and total hip arthroplasty (THA) is difficult, and is further complicated in the setting of poor femoral bone stock. We present a case of supracondylar fracture between THA and long-stemmed TKA femoral components in a patient with rheumatoid arthritis, deficient metaphyseal bone stock, and recurrent fractures. A long custom intramedullary intercalating component was devised to link the well-fixed existing THA stem to a revision distal femoral component. The resulting construct was stable and allowed for full weight-bearing ambulation, representing a useful treatment option in the management of periprosthetic fractures between revision TKA and well-fixed THA.
Medical subject headings
- Femoral Fractures
- Fracture Fixation, Intramedullary
- Periprosthetic Fractures
Anatomy
- femur
- knee
- hip