Transatrial antegrade approach for double mitral and tricuspid "valve-in-ring" implantation.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 23272889.
- Also identified by DOI 10.1016/j.athoracsur.2012.09.092.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Within the last 5 years, the number of transcatheter aortic valve implantation (TAVI) procedures has increased continuously and, in parallel, the indications for TAVI have expanded (eg, failing surgical valves and rings). Furthermore, alternative TAVI access routes such as transaxillary and transaortic have been applied successfully. We report on, to our knowledge, the first-in-human case of a combined off-pump antegrade transatrial implantation of a transcatheter valve within a mitral and tricuspid annuloplasty ring through an anterolateral minithoracotomy. The patient showed severe mitral valve and tricuspid valve stenosis and regurgitation 15 years after mitral valve repair and 7 years after aortic valve replacement and tricuspid valve repair.
Medical subject headings
- Cardiac Catheterization
- Heart Valve Prosthesis Implantation
- Mitral Valve
- Mitral Valve Insufficiency
- Tricuspid Valve
- Tricuspid Valve Insufficiency