Novel CT-based three-dimensional software improves the characterization of cam morphology.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 23361933.
- Also identified by DOI 10.1007/s11999-013-2809-x and PMC identifier 3705074.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Incomplete correction of femoral offset and sphericity remains the leading cause for revision surgery for symptomatic femoroacetabular impingement (FAI). Because arthroscopic exploration is technically difficult, a detailed preoperative understanding of morphology is of paramount importance for preoperative decision-making. The purposes of this study were to (1) characterize the size and location of peak cam deformity with a prototype CT-based software program; (2) compare software alpha angles with those obtained by plain radiograph and CT images; and (3) assess whether differences can be explained by variable measurement locations. We retrospectively reviewed the preoperative plain radiographs and CT scans of 100 symptomatic cam lesions treated by arthroscopy; recorded alpha angle and clockface measurement location with a novel prototype CT-based software program, CT, and Dunn lateral plain radiographs; and used ordinary least squares regressions to assess the relationship between alpha angle and measurement location. The software determined a mean alpha angle of 70.8° at 1:23 o'clock and identified 60% of maximum alpha angles between 12:45 and 1:45. The CT and plain radiographs underestimated by 5.7° and 8.2°, respectively. The software-based location was anterosuperior to the mean CT and plain radiograph measurement locations by 41 and 97 minutes, respectively. Regression analysis confirmed a correlation between alpha angle differences and variable measurement locations. Software-based three-dimensional (3-D) imaging generated alpha angles larger than those found by plain radiograph and CT, and these differences were the result of location of measurement. An automated 3-D assessment that accurately describes the location and topography of FAI may be needed to adequately characterize preoperative deformity.
Medical subject headings
- Femoracetabular Impingement
- Hip Joint
- Imaging, Three-Dimensional
- Radiographic Image Interpretation, Computer-Assisted
- Software
- Tomography, X-Ray Computed
Anatomy
- femur
- hip