Automatic segmentation and measurement of pleural effusions on CT.
Where this comes from
- Record sourced from PubMed, PMID 23372069.
- Also identified by DOI 10.1109/TBME.2013.2243446 and PMC identifier 4398573.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Pleural effusion is an important biomarker for the diagnosis of many diseases. We develop an automated method to evaluate pleural effusion on CT scans, the measurement of which is prohibitively time consuming when performed manually. The method is based on parietal and visceral pleura extraction, active contour models, region growing, Bezier surface fitting, and deformable surface modeling. Twelve CT scans with three manual segmentations were used to validate the automatic segmentation method. The method was then applied on 91 additional scans for visual assessment. The segmentation method yielded a correlation coefficient of 0.97 and a Dice coefficient of 0.72±0.13 when compared to a professional manual segmentation. The visual assessment estimated 83% cases with negligible or small segmentation errors, 14% with medium errors, and 3% with large errors.
Medical subject headings
- Algorithms
- Pattern Recognition, Automated
- Pleural Effusion
- Radiographic Image Enhancement
- Radiographic Image Interpretation, Computer-Assisted
- Radiography, Thoracic
- Tomography, X-Ray Computed