Biomechanical comparison of open and arthroscopic Latarjet procedures.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 23395468.
- Also identified by DOI 10.1016/j.arthro.2012.12.003.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To biomechanically compare the effectiveness of the standard open and arthroscopic techniques of the Latarjet procedure to address a critical anterior glenoid defect in combination with a capsular insufficiency. Translation testing of 12 human cadaveric shoulder specimens was performed in a robot-assisted setup under 3 different conditions: (1) intact/vented shoulder joint, (2) combined anterior glenoid bone and capsular defect, and (3) open and arthroscopic Latarjet procedures. Testing was performed for each condition in 2 test positions: 60° of glenohumeral abduction with neutral rotation (ABD position) and 60° of abduction and external rotation (ABER position). Each position was tested with a passive humerus load of 30 N in the anterior, inferior, and anteroinferior directions. Translational movement of the humeral head was evaluated with and without the application of a 10-N load to the conjoint tendon (CJT). In the ABD position, translations after the open Latarjet procedure significantly differed from the arthroscopic technique in the anterior and anteroinferior directions when testing was performed with loading of the CJTs (CJT loading). Without CJT loading, the open Latarjet technique showed significantly lower translations in the anterior, inferior (P = .004), and anteroinferior (P = .001) testing directions in the ABD position. In the ABER position, the arthroscopic procedure showed no significant difference compared with the standard open procedure. We found a superior stabilization effect of the open Latarjet technique in the ABD position. The difference is ascribed to the anterior capsular repair, which was performed within the open technique and omitted during the arthroscopic procedure. The reduction of translation in a pure abduction position of the arm is more effectively performed with a conventional open Latarjet technique that includes a capsular repair. In combined ABER position, there was no difference found between the open and arthroscopic Latarjet techniques.
Medical subject headings
- Joint Instability
- Shoulder Joint
Anatomy
- shoulder