Relevance of a press-fit dual mobility cup to deal with recurrent dislocation of conventional total hip arthroplasty: a 29-case series.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 23412147.
- Also identified by DOI 10.1007/s00590-012-1002-3.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The aim of this paper was to assess the impact on stability of revision of 29 standard acetabular cups to press-fit uncemented dual mobility (DM) cups in THAs with recurrent dislocation. This series was composed of 17 women and 12 men aged on average 75.6 ± 8.1 years (55-88), operated on between November 2000 and July 2010. The average number of dislocations before revision surgery was 3.87 ± 1.79 (2-10), and the average time from primary procedure to revision was 6.6 ± 4.3 years (45-15 years). 9 patients (31.03 %) had already undergone one or more procedures for instability prior to revision to DM cup. All patients were reviewed at an average time of 46 ± 28 months (range: 17 months-11 years). Only one patient had redislocated in this time (3.4 %). This patient underwent a simple closed reduction and did not dislocate again. IV retrospective cohort study.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Hip Dislocation
- Prosthesis Failure
- Reoperation
Anatomy
- hip