Volume estimation of the aortic sac after EVAR using 3-D ultrasound - a novel, accurate and promising technique.

Bredahl, K; Long, A; Taudorf, M; Lönn, L; Rouet, L; Ardon, R; Sillesen, H; Eiberg, J P · Eur J Vasc Endovasc Surg · 2013

prospective_cohort · Level II

Where this comes from

Abstract

Volume estimation is more sensitive than diameter measurement for detection of aneurysm growth after endovascular aneurysm repair (EVAR), but this has only been confirmed on three-dimensional, reconstructed computer tomography (3-D CT). The potential of 3-D ultrasound (3-D US) for volume estimation in EVAR surveillance is unknown. Prospective validation study comparing 3-D US with 3-D CT, using 3-D CT as the gold standard. From August 2011 to March 2012, 93 consecutive EVAR patients were enrolled and examined with both 3-D US and CT angiography (CTA). Image data were analysed in a mutual blinded setup using a 3-D interactive segmentation technique. The technical success rate of 3D-US was 98% (91/93). In 91 EVAR patients (F/M; 10/81) eligible for further analysis, the mean maximum volume (SD) was 126 (58) ml using 3-D US and 128 (58) ml using 3-D CT. The mean difference was 1 ml (0.4%) and the limits of agreement were -14 to 16 ml (-11; 12%). Volume estimation of the aortic sac after EVAR using 3-D US is a feasible and accurate method using 3-D CT as the gold standard.

Medical subject headings