Successful transapical implantation of an Edwards Sapien valve within an insufficient aortic CoreValve prosthesis: an initial experience.

Schleger, Simone; Kasel, Markus; Vogel, Jayshree; Lieber, Michael; Antoni, Dietmar; Hoffmann, Ellen; Eichinger, Walter B · Ann Thorac Surg · 2013

case_report · Level V

Where this comes from

Abstract

Transcatheter aortic valve implantation (TAVI) has become an emerging alternative for high-risk patients with aortic stenosis unsuitable for surgical intervention. We report the case of a 26-mm Edwards Sapien valve (Edwards Lifesciences, Irvine, CA) implanted into an insufficient 29-mm CoreValve prosthesis (Medtronic Inc, Minneapolis, MN) 1 year after implantation using the transapical approach in a 59-year-old man. Transesophageal echocardiography showed severe paravalvular regurgitation and computed tomography revealed the CoreValve to be located slightly below the aortic annulus with evidence of underdeployment. The balloon-expandable Sapien system caused a better expansion of the underdeployed CoreValve and the pericardial skirt adequately covered the leakage. The paravalvular regurgitation disappeared and the patient recovered.