By using a high-pressure liquid chromatography assay, we investigated the ability of collagen shield therapeutic contact lenses to release amphotericin B and deliver it to the anterior segment of rabbit eyes. In vitro studies showed that presoaked collagen shields released most of the amphotericin B within the first hour of elution. We compared the corneal and aqueous humor amphotericin B levels produced by collagen shields soaked in amphotericin B and frequent-drop therapy at four time points over a six-hour period. The collagen shields soaked in amphotericin B produced corneal levels that were higher than those produced by frequent-drop therapy at one hour, equivalent to drop therapy at two and three hours, and lower than drop therapy at six hours. There were no differences in amphotericin B levels in aqueous humor at any time point between rabbits treated with collagen shield delivery and rabbits treated with frequent-drop delivery. The results of this study suggest that amphotericin B delivery to the cornea by collagen shields is comparable to frequent-drop delivery but has the potential benefit of added convenience and compliance.