A pilot study of video-motion analysis in endovascular surgery: development of real-time discriminatory skill metrics.
other · Level V
Where this comes from
- Record sourced from PubMed, PMID 23465454.
- Also identified by DOI 10.1016/j.ejvs.2013.02.004.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Accurate assessment and credentialing of physicians is essential. Objective motion analysis of guide-wire/catheter manipulation to assess proficiency during endovascular interventions remains unexplored. This study aims to assess its feasibility and its role in evaluation of technical ability. A semi-automated catheter-tracking software was developed which allows for frame-by-frame motion analysis of fluoroscopic videos and calculation 2D catheter tip path-length. 21 interventionalists (6 cardiologists, 8 interventional radiologists, 7 vascular surgeons; 14/21 had performed >500 endovascular procedures) performed an identical carotid artery stenting procedure (CAS) on a VIST simulator (Mentice, Gothenburg, Sweden). Operators were sub-divided into four categories according to CAS experience: 6 inexperienced (0 CAS-group A), 3 low-volume (1-20 CAS-group B), 5 moderate-volume (21-50 CAS-group C) and 7 high-volume (>50 CAS-group D) CAS experience. Total PL was calculated for each case and comparisons made between groups. PL was correlated with: quantitative, simulator-derived metrics and qualitative performance scores (generic and procedure-specific) derived from post-hoc video analysis by three blinded observers. Group D used 5160.3 (inter-quartile range- IQR 4046.4-7142.9) pixels of movement, compared to 6856.7 (5914.4-8106.9) for group A (p = 0.046); 10,905.1 (7851.1-14,381.5) for group B (p = 0.017); and 9482.6 (8663.5-13,847.6) for group C (p = 0.003). Statistically significant inverse correlations were seen between total PL and qualitative performance scores (rho = -0.519 for generic (p = 0.027) rho = -0.567 for procedure-specific (p = 0.014) scores). PL did not correlate with any of the simulator-derived metrics (errors, contrast volume, total procedure and fluoroscopy times, cine-loops used). Endovascular instrument video motion analysis is feasible and may represent a valuable tool for the objective assessment of endovascular skill.
Medical subject headings
- Clinical Competence
- Endovascular Procedures
- Videotape Recording