A simple protocol to prevent external ventricular drain infections.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 23467249.
- Also identified by DOI 10.1227/NEU.0b013e31828e8dfd.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
External ventricular drains (EVDs) are associated with high rates of infection, and EVD infections cause substantial morbidity and mortality. To determine whether the introduction of an evidence-based EVD infection control protocol could reduce the rate of EVD infections. This was a retrospective analysis of an EVD infection control protocol introduced in a tertiary care neurointensive care unit. We compared rates of cerebrospinal fluid culture positivity and ventriculitis for the 3 years before and 3 years after the introduction of an evidence-based EVD infection control protocol. A total of 262 EVD placements were analyzed, with a total of 2499 catheter-days. The rate of cerebrospinal fluid culture positivity decreased from 9.8% (14 of 143; 11.43 per 1000 catheter-days) at baseline to 0.8% (1 of 119; 0.79 per 1000 catheter-days) in the EVD infection control protocol period (P = .001). The rate of ventriculitis decreased from 6.3% (9 of 143; 7.35 per 1000 catheter-days) to 0.8% (1 of 119; 0.79 per 1000 catheter-days; P = .02). The introduction of a simple, evidence-based infection control protocol was associated with a dramatic reduction in the risk of EVD infection.
Medical subject headings
- Catheter-Related Infections
- Cerebrospinal Fluid Shunts
- Infection Control