Migration of Bakri balloon through an unsuspected uterine perforation during the treatment of secondary postpartum hemorrhage.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 23470856.
- Also identified by DOI 10.1016/j.ajog.2013.02.052.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The current case describes an unreported complication of Bakri balloon placement: the migration of the Bakri balloon to the broad ligament through an unsuspected uterine rupture. Finally, a hysterectomy had been required. The Bakri balloon may be involuntary introduced in an unexpected uterine rupture, even if the balloon is placed with ultrasound guidance.