In vitro electro-mechanical characterization of human knee articular cartilage of different degeneration levels: a comparison with ICRS and Mankin scores.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 23477790.
- Also identified by DOI 10.1016/j.jbiomech.2013.02.004.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
In the present study, the electro-mechanical properties of human knee articular cartilage were measured in vitro. An arthroscopic measurement tool was used to measure streaming potential integral (SPI), after which creep indentation tests were performed. Additionally, degradation level of the tissue was determined in accordance with the International Cartilage Repair Society (ICRS score), and hematoxylin/eosin and safranin O staining were performed to determine the Mankin score. Mechanical test results were evaluated both analytically and by means of a finite-element-optimized parameter identification procedure. The SPI was then correlated with poroelastic E modulus (r=0.563, p<0.008, n=22), natural logarithm of hydraulic permeability (r=0.374, p<0.095, n=22) and cartilage degeneration scores (ICRS and Mankin) (r=-0.749, p<0.000, n=22 and r=-0.409, p<0.059, n=22 respectively).
Medical subject headings
- Arthroscopy
- Cartilage, Articular
- Elastic Modulus
- Knee Joint