Initial implant stability predicts migration but not failure in cementless acetabular revision with bone grafting.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 23489733.
- Also identified by DOI 10.1016/j.arth.2012.10.010.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Host bone contact of less than 50% is perceived but not proven to cause migration and loosening after acetabular revision. A prospective analysis of cementless acetabular revision cases with impaction grafting was performed to determine if this was an independent risk factor for these events. Sixty-two hips in 54 patients were assessed at a mean follow-up of 84.5 months (range 61-112) yielding a probability of 94.6% of retaining the acetabular component using revision for aseptic loosening as the end point. No single factor was independently causative for loosening, although Type III fixation was associated with migration (p=0.0159); subanalysis suggested that achieving host-bone contact in at least part of the dome and posterior column is important.
Medical subject headings
- Acetabulum
- Arthroplasty, Replacement, Hip
- Bone Transplantation
- Hip Prosthesis
Anatomy
- hip
- pelvis