Severe tissue destruction in the ear caused by alkaline button batteries.

Premachandra, D J; McRae, D · Postgrad Med J · 1990

case_report · Level V

Where this comes from

Abstract

Button batteries spontaneously leak corrosive electrolyte solution on exposure to moisture. Tissue in contact with such solution will undergo liquefaction necrosis. Three cases of skin, bone and tympanic membrane necrosis caused by a leaking button battery lodged in the external auditory meatus are described.