High-volume hydrodissection: increasing the safety and efficiency of perforator dissection.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 23511744.
- Also identified by DOI 10.1097/SAP.0b013e31827039f6.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Although perforator flaps have advanced the field of reconstructive microsurgery, these flaps increase operative time and difficulty of dissection. A prospective experimental animal study was performed to study the use of high-volume hydrodissection to simultaneously decrease the operative time while increasing the safety of perforator dissection. Sixteen Sprague-Dawley rats underwent bilateral "deep inferior epigastric perforator" flap dissections with hydrodissection used on the study side and a traditional dissection performed on the control side. Primary outcome measurements included dissection time and dissection difficulty score (1-5 in order of increasing difficulty). The mean (SD) dissection time for the hydrodissected perforators was 9.29 (2.50) minutes versus 13.22 (2.44) minutes for the control perforators (P < 0.001). The mean (SD) dissection difficulty score was 4.44 (0.73) for the dissection of the control side compared with 1.69 (0.87) for the hydrodissected side (P < 0.001). The mechanical benefits of hydrodissection of perforators were evident in reduction of perforator dissection time and difficulty.
Medical subject headings
- Dissection
- Epigastric Arteries
- Microsurgery
- Perforator Flap