Incidence of bacterial contamination in primary THA and combined hardware removal: analysis of preoperative aspiration and intraoperative biopsies.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 23523208.
- Also identified by DOI 10.1016/j.arth.2013.02.017.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Prior fracture surgery in the setting of subsequent arthroplasty may confer an increased risk of infection. The current authors retrospectively reviewed 122 patients from 2006 to 2010. Joint aspirations performed preoperatively in two of 52 patients revealed bacterial growth. Preoperative CRP levels were elevated in 22.8% with a mean value of 10.4 mg/L (range 5.5 to 33.3). Intra-operative cultures were performed in 109 patients, with a single patient sample exhibiting bacterial growth (0.9%). Preoperative aspiration showed a sensitivity of 1.0 and specificity of 0.98 (P<0.039) for bacterial contamination. There was no postoperative periprosthetic infection noted. In conclusion the retrieval of internal fixation devices and total hip arthroplasty can be performed safely as a single stage procedure without significantly increasing the risk of periprosthetic infection.
Medical subject headings
- Femoral Fractures
- Hip Prosthesis
- Joint Diseases
- Prosthesis-Related Infections
Anatomy
- hip
- femur