Anterior interbody fusion of the cervical spine with Zero-P spacer: prospective comparative study-clinical and radiological results at a minimum 2 years after surgery.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 23524869.
- Also identified by DOI 10.1097/BRS.0b013e3182913400.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A prospective study. The aim of this study was to compare clinical and radiological efficacy of anterior cervical microdiscectomy and fusion done by the newly designed low-profile interbody spacer in cases of symptomatic cervical spine spondylosis. There are basically 2 ways to provide interbody fusion in the degenerative cervical spine; the first is by way of an unanchored "stand-alone" bone graft or cage, and the second is with bone graft or a cage anchored with a plate. Both concepts have their own benefits as well as potential drawbacks. Low-profile angle-stable spacer Zero-P is an implant that can potentially limit the drawbacks of both these procedures. METHODS.: Prospective study collecting clinical and radiological data of 77 patients undergoing anterior cervical interbody fusion of 1 or 2 motion segments from C3-C7 was performed. Zero-P spacer was used in 44 patients (55 segments) and in 33 cases (41 segments), stabilization was done using interbody spacer and dynamic anterior cervical plate. Patients were followed a minimum of 2 years after surgery. There was no significant difference in neck disability index values, presence of dysphagia (P = 0.308), and Cobb C values during follow-up (P = 0.051) between both groups. A significant difference in the first 2 values of Cobb S was found (P < 0.001), but the next course of Cobb S changes showed no difference in either group. No difference was found in the radiological stability during follow-up, and no revision surgery was done. The results of this study confirm biomechanical assumptions associated with the Zero-P spacer. Implantation of this new cage results in setting required biomechanical conditions in the treated segment that are comparable with those when the segment is treated with a dynamic plate. However, the potential of the mentioned implant to reduce the incidence of postoperative dysphagia was not proven on this sample of patients.
Medical subject headings
- Cervical Vertebrae
- Prostheses and Implants
- Spinal Fusion
Anatomy
- cervical spine