Use of apneic oxygenation for the performance of pan-endoscopy.

Rudlof, Burkard; Hohenhorst, Winfried · Otolaryngol Head Neck Surg · 2013

retrospective_cohort · Level III

Where this comes from

Abstract

To evaluate the efficacy of apneic oxygenation for the performance of pan-endoscopy. Clinical retrospective study. A university teaching hospital in Wuppertal, Germany. Forty-seven patients who underwent pan-endoscopy under apneic oxygenation during a period of 1 year. After preoxygenation and induction of anesthesia, an 8 French catheter was introduced into the trachea for oxygen supply. Pan-endoscopy was carried out, as long as there were no signs of desaturation. The data were collected retrospectively from the anesthesia charts. Apnea was well tolerated up to 45 minutes in most of the patients. In 2 patients, the method was carried out incorrectly, and in 1 obese patient, it was not possible to get an acceptable oxygenation. With appropriate monitoring, sufficient nitrogen elution, and proper patient selection, we believe that this technique is superior to jet ventilation and intubation for pan-endoscopy, allowing unimpeded operative visualization.