Diagnostic accuracy of 2- and 3-dimensional computed tomography and solid modeling of coronoid fractures.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 23594717.
- Also identified by DOI 10.1016/j.jse.2013.02.009.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This study measured the diagnostic performance characteristics and reliability of 2-dimensional (2DCT) and 3-dimensional (3DCT) computed tomography images and modeling of coronoid fractures. The treating surgeon and first assistant evaluated 28 fractures for fracture type, specific characteristics, and proposed treatment. The observers evaluated the fractures 4 times: first based upon 2DCT computed images and radiographs; second with the addition of 3DCT images; third with the addition of 3D models; and finally based upon intra-operative exposure, which was considered the reference standard. The diagnostic performance characteristics did not improve with more sophisticate imaging and models. The addition of 3DCT reconstructions improved the inter-observer reliability for fracture classification, characteristics, and proposed treatment. More sophisticated images and modeling improved reliability but not accuracy when characterizing coronoid fractures.
Medical subject headings
- Fractures, Bone
- Image Processing, Computer-Assisted
- Imaging, Three-Dimensional
- Tomography, X-Ray Computed