Use of femoral locking plate for salvage of failed ankle arthoplasty after trauma.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 23621980.
- Also identified by DOI 10.1053/j.jfas.2013.02.010.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
When total ankle arthroplasty fails, few good options are available for salvage. We report a case of total ankle arthroplasty displacement after trauma. The injury was initially repaired with an anterior ankle arthrodesis plate for ankle fusion. On the follow-up radiographs taken during the fourth postoperative week, internal fixation failure was noted. A second revision was undertaken, using a femoral locking plate to obtain tibiotalocalcaneal fusion. We present this case as an alternative method for developing a stable construct in revising total ankle take down.
Medical subject headings
- Ankle Injuries
- Arthroplasty, Replacement, Ankle
- Femur
Anatomy
- ankle
- femur