Wiener filtering improves quantification of regional myocardial perfusion with thallium-201 SPECT.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 2362203.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Quantitation of myocardial perfusion with thallium-201 (201Tl) SPECT is limited by finite resolution and image noise. This study examined whether Wiener filtering could improve quantitation of the severity of myocardial perfusion deficits. In 19 anesthetized dogs, adjustable stenoses were placed on the left anterior descending (LAD, n = 12) or circumflex (LCx, n = 7) arteries. Thallium-201 SPECT images were acquired during maximal coronary vasodilation with dipyridamole, and simultaneous measurements of myocardial blood flow were made with microspheres. The relationship between SPECT and microsphere flow deficits in the LAD region was significantly better (p less than 0.05) with Wiener filtering (Y = 0.90X + 0.03, r = 0.78) than with conventional Hanning filtering (Y = 0.66X + 0.34, r = 0.61). Similarly, in the LCx region the relationship between SPECT and microsphere perfusion deficits was better (p less than 0.01) with the Wiener filter (Y = 0.91X + 0.07, r = 0.66) than with the Hanning filter (Y = 0.36X + 0.50, r = 0.40). Wiener filtering improves quantitation of the severity of regional myocardial perfusion deficits, allowing better assessment of the functional significance of coronary artery stenoses.
Medical subject headings
- Coronary Circulation
- Heart
- Image Enhancement
- Tomography, Emission-Computed, Single-Photon