Porous tantalum tibial component prevents periprosthetic loss of bone mineral density after total knee arthroplasty for five years-a matched cohort study.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 23642446.
- Also identified by DOI 10.1016/j.arth.2013.03.031.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
In 21 knees receiving porous tantalum tibial component and 21 knees receiving a cemented cobalt-chromium tibial component, dual x-ray absorptiometry scans were performed for five years post-operatively. The postoperative decrease in the bone mineral density in the lateral aspect of the tibia was significantly less in knees with porous tantalum tibial components (11.6%) than in knees with cemented cobalt-chromium tibial components (29.6%) at five years (p < 0.05). No prosthetic migration or periprosthetic fracture was detected in either group. The present study is one of the studies with the longest follow-up period on bone mineral density after total knee arthroplasty. Porous tantalum tibial component has a favorable effect on the bone mineral density of the proximal tibia after total knee arthroplasty up to five years.