Electronic cleansing for 24-h limited bowel preparation CT colonography using principal curvature flow.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 23674411.
- Also identified by DOI 10.1109/TBME.2013.2262046.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
CT colonography (CTC) is one of the recommended methods for colorectal cancer screening. The subject's preparation is one of the most burdensome aspects of CTC with a cathartic bowel preparation. Tagging of the bowel content with an oral contrast medium facilitates CTC with limited bowel preparation. Unfortunately, such preparations adversely affect the 3-D image quality. Thus far, data acquired after very limited bowel preparation were evaluated with a 2-D reading strategy only. Existing cleansing algorithms do not work sufficiently well to allow a primary 3-D reading strategy. We developed an electronic cleansing algorithm, aimed to realize optimal 3-D image quality for low-dose CTC with 24-h limited bowel preparation. The method employs a principal curvature flow algorithm to remove heterogeneities within poorly tagged fecal residue. In addition, a pattern recognition-based approach is used to prevent polyp-like protrusions on the colon surface from being removed by the method. Two experts independently evaluated 40 CTC cases by means of a primary 2-D approach without involvement of electronic cleansing as well as by a primary 3-D method after electronic cleansing. The data contained four variations of 24-h limited bowel preparation and was based on a low radiation dose scanning protocol. The sensitivity for lesions ≥ 6 mm was significantly higher for the primary 3-D reading strategy (84%) than for the primary 2-D reading strategy (68%) (p = 0.031). The reading time was increased from 5:39 min (2-D) to 7:09 min (3-D) (p = 0.005); the readers' confidence was reduced from 2.3 (2-D) to 2.1 (3-D) ( p = 0.013) on a three-point Likert scale. Polyp conspicuity for cleansed submerged lesions was similar to not submerged lesions (p = 0.06). To our knowledge, this study is the first to describe and clinically validate an electronic cleansing algorithm that facilitates low-dose CTC with 24-h limited bowel preparation.
Medical subject headings
- Algorithms
- Colonography, Computed Tomographic
- Imaging, Three-Dimensional
- Pattern Recognition, Automated