Interobserver variability and feasibility of polymerase chain reaction-based assay in distinguishing ischemic colitis from Clostridium difficile colitis in endoscopic mucosal biopsies.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 23690114.
- Also identified by DOI 10.1309/AJCPG8AYN9MUWJXV.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Polymerase chain reaction (PCR)-based assays using stool samples are currently the most effective method of detecting Clostridium difficile. This study examines the feasibility of this assay using mucosal biopsy samples and evaluates the interobserver reproducibility in diagnosing and distinguishing ischemic colitis from C difficile colitis. Thirty-eight biopsy specimens were reviewed and classified by 3 observers into C difficile and ischemic colitis. The findings were correlated with clinical data. PCR was performed on 34 cases using BD GeneOhm C difficile assay. The histologic interobserver agreement was excellent (κ= 0.86) and the agreement between histologic and clinical diagnosis was good (κ = 0.84). All 19 ischemic colitis cases tested negative (100% specificity) and 3 of 15 cases of C difficile colitis tested positive (20% sensitivity). C difficile colitis can be reliably distinguished from ischemic colitis using histologic criteria. The C difficile PCR test on endoscopic biopsy specimens has excellent specificity but limited sensitivity.
Medical subject headings
- Clostridium Infections
- Colitis, Ischemic
- Enterocolitis, Pseudomembranous
- Intestinal Mucosa