Right atrial perforation by a temporary epicardial pacing wire.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 2369218.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Cardiac perforation by an epicardial pacing wire is an extremely rare event. A case of right atrial perforation occurring 10 hours after coronary artery bypass grafting is reported. Another cause of bleeding and cardiac tamponade after cardiac operation is therefore illustrated.