Hybrid imaging of peripheral skeletal disease by SPECT/high-resolution flat-panel CT.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 23704320.
- Also identified by DOI 10.2967/jnumed.112.116343.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The aim of this study was to determine the impact of high-resolution cone-beam CT with flat-panel detectors on the interpretation of bone SPECT in diseases of the peripheral skeleton. Forty-one consecutive patients with peripheral skeletal disease were examined with a SPECT/high-resolution CT system providing isotropic voxels of 0.33 × 0.33 × 0.33 mm. High-resolution images were retrospectively analyzed by 2 readers and compared with low-resolution images obtained by filtering the high-resolution images to a lower resolution. SPECT/high-resolution CT demonstrated higher diagnostic confidence scores (1.98 ± 0.27 vs. 1.3 ± 0.45, P < 0.01) and better interobserver agreement (κ = 0.5 vs. 0.2) than SPECT/low-resolution CT. The diagnosis made by SPECT/high-resolution CT was in agreement with the final clinical diagnosis in 95% (reader 1) and 90% (reader 2) of the cases, as compared with 59% (reader 1) and 60% (reader 2) of the cases for SPECT/low-resolution CT (P < 0.01). High-resolution flat-panel CT has the potential to significantly improve SPECT/CT imaging in diseases of the peripheral skeleton.
Medical subject headings
- Bone Diseases
- Multimodal Imaging
- Positron-Emission Tomography
- Tomography, X-Ray Computed