Fatigue property of a bioabsorbable magnesium alloy with a hydroxyapatite coating formed by a chemical solution deposition.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 23727947.
- Also identified by DOI 10.1016/j.jmbbm.2013.04.021.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A hydroxyapatite (HAp) coating was directly formed on an extruded AZ31 magnesium alloy by a single-step chemical solution deposition. The HAp coating consists of an outer porous HAp layer, an inner continuous HAp layer, and a thin intermediate MgO layer, and the inner HAp and MgO layers are composed of nanocrystals. Tensile and fatigue tests were performed on the HAp-coated AZ31 in air. The HAp coating microscopically showed neither crack nor detachment at 5% static elongation (1.5% residual strain). With further elongation under tensile stress, cracks were formed perpendicularly to the tensile direction, and fragments of the coating detached with a fracture inside the inner continuous HAp layer. The fatigue strengths at 10(7) cycles (fatigue limit) of HAp-coated and mechanically polished AZ31 were ca. 80 MPa and ca. 90 MPa, respectively. The slight decrease in the fatigue limit with the HAp coating is attributed to small pits with a depth of ca. 10 μm formed on the substrate during the HAp-coating treatment. The HAp coating remained on the specimen without cracks after 10(7) cycles at the fatigue limit, which provides ca. 3% cyclic elongation.
Medical subject headings
- Absorbable Implants
- Alloys
- Coated Materials, Biocompatible
- Durapatite
- Magnesium