Simultaneous dual-isotope SPECT/CT with (99m)Tc- and (111)In-labelled albumin microspheres in treatment planning for SIRT.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 23771601.
- Also identified by DOI 10.1007/s00330-013-2916-9.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To investigate simultaneous dual-isotope SPECT/CT with two differently radioisotope-labelled albumin-microsphere fractions for treatment planning of hepatic radioembolisation. In addition to (99m)Technetium-labelled albumin microspheres (commercially available), we performed labelling with (111)Indium. Binding stability of (111)Indium-labelled microspheres was tested in vitro and in vivo in mice. Simultaneous dual-isotope SPECT/CT imaging was validated in an anthropomorphic torso phantom; subsequently, dual-isotope SPECT/CT was performed under in-vivo conditions in pigs (n = 3) that underwent transarterial injection of (99m)Technetium- and (111)Indium-labelled microspheres in the liver (right and left hepatic artery, respectively), in both kidneys and in the gluteal musculature. In total, n = 18 transarterial injections were performed. In-vitro testing and in-vivo studies in mice documented high binding stability for both (99m)Technetium-labelled and (111)Indium-labelled microsphere fractions. In phantom studies, simultaneous dual-isotope SPECT/CT enabled reliable separation of both isotopes. In pigs, the identified deposition of both isotopes could be accurately matched with intended injection targets (100 %, 18/18 intended injection sites). Furthermore, an incidental deposition of (99m)Technetium-labelled microspheres in the stomach could be correlated to the test injection into a right hepatic artery. Simultaneous dual-isotope SPECT/CT after transarterial injection with (99m)Technetium- and (111)Indium-labelled microspheres is feasible. Thus, it may offer additional, valuable information compared to single (99m)Technetium-labelled albumin examinations. • Simultaneous dual-isotope SPECT/CT with (111) In- and (99m) Tc-labelled albumin microspheres is feasible. • Differentiation of two microsphere fractions after transarterial injection is possible. • The origin of an extra-hepatic microsphere deposition can be correlated to the corresponding artery. • This technique could reduce the setup time for selective internal radiation treatment.
Medical subject headings
- Chemoembolization, Therapeutic
- Indium Radioisotopes
- Liver Neoplasms, Experimental
- Radiotherapy Planning, Computer-Assisted
- Technetium Tc 99m Sestamibi
- Tomography, Emission-Computed, Single-Photon
- Tomography, X-Ray Computed