The use of O-(2-18F-fluoroethyl)-L-tyrosine PET for treatment management of bevacizumab and irinotecan in patients with recurrent high-grade glioma: a cost-effectiveness analysis.
other · Level V
Where this comes from
- Record sourced from PubMed, PMID 23785172.
- Also identified by DOI 10.2967/jnumed.113.120089.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To date, the use of structural MR imaging (including contrast-enhanced and T2-weighted or fluid-attenuated inversion recovery-weighted images) is the standard method to diagnose tumor progression and to assess antiangiogenic treatment effects. However, several studies have suggested that O-(2-(18)F-fluoroethyl)-L-tyrosine ((18)F-FET) PET adds valuable clinical information to the information derived from structural MR imaging alone. We evaluated the effectiveness and cost-effectiveness of the addition of (18)F-FET PET to structural MR imaging for the management of treatment with bevacizumab and irinotecan (BEV/IR) in patients with recurrent high-grade glioma compared with MR imaging alone from the perspective of the German Statutory Health Insurance. To evaluate the incremental cost-effectiveness of the additional use of (18)F-FET PET, a decision tree model was used. Effectiveness of (18)F-FET PET was defined as correct identification of both tumor progression before BEV/IR treatment initiation and BEV/IR treatment response and was evaluated for the combination of (18)F-FET PET and MR imaging compared with MR imaging alone. Costs were estimated for a baseline scenario and for a more expensive scenario. The robustness of the results was tested using deterministic and probabilistic sensitivity analyses. The use of (18)F-FET PET resulted in a number needed to diagnose of 2.4, that is, 3 additional patients have to be diagnosed to avoid 1 wrong diagnosis. The incremental cost-effectiveness ratio of (18)F-FET PET/MR imaging compared with MR imaging alone was €5,725 (€1 ≈ $1.30) for the baseline scenario and €8,145 for the more expensive scenario per additional correct diagnosis. The probabilistic sensitivity analysis confirmed the robustness of the results. The model suggests that the additional use of (18)F-FET PET in the management of patients with recurrent high-grade glioma treated with BEV/IR may be cost-effective. Integration of (18)F-FET PET has the potential to avoid overtreatment and corresponding costs, as well as unnecessary side effects to the patient.
Medical subject headings
- Antibodies, Monoclonal, Humanized
- Brain Neoplasms
- Camptothecin
- Decision Trees
- Glioma
- Positron-Emission Tomography
- Tyrosine