Schultz metacarpophalangeal arthroplasty: a long-term follow-up study.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 2380530.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We describe a prospective, long-term evaluation of the Schultz metacarpophalangeal joint implant. The prosthesis is a semiconstrained, cemented implant with a ball-in-socket articulation. Thirty-six implants were followed for an average of 10.9 years. There was a progressive decrease in range of motion and strength and a recurrence of ulnar deviation. The neck of the proximal phalangeal component fractured in 39% of the joints. Periarticular heterotopic bone formed in all joints, but was extensive in only 22%. Although some lucency of the bone-cement interface was seen in 80% of the joints, no prosthetic loosening occurred in this series. Our results indicate that long-term, intramedullary cement fixation of relatively long-stemmed components can be satisfactory. However, the articulated portion of this implant does not consistently withstand the stresses transmitted across the joint and does not provide long-term joint stability.
Medical subject headings
- Arthritis, Rheumatoid
- Joint Prosthesis
- Metacarpophalangeal Joint
Anatomy
- hand