Changes in tibial bone density measured from standard radiographs in cemented and uncemented total knee replacements after ten years' follow-up.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 23814242.
- Also identified by DOI 10.1302/0301-620X.95B7.30537.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Stress shielding resulting in diminished bone density following total knee replacement (TKR) may increase the risk of migration and loosening of the prosthesis. This retrospective study was designed to quantify the effects of the method of fixation on peri-prosthetic tibial bone density beneath cemented and uncemented tibial components of similar design and with similar long-term survival rates. Standard radiographs taken between two months and 15 years post-operatively were digitised from a matched group of TKRs using cemented (n = 67) and uncemented (n = 67) AGC tibial prostheses. Digital radiograph densitometry was used to quantify changes in bone density over time. Age, length of follow-up, gender, body mass index and alignment each significantly influenced the long-term pattern of peri-prosthetic bone density. Similar long-term changes in density irrespective of the method of fixation correlated well with the high rate of survival of this TKR at 20 years, and suggest that cemented and uncemented fixation are both equally viable.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Bone Cements
- Bone Density
- Cementation
- Knee Joint
- Prosthesis Design
- Tibia
Anatomy
- knee
- tibia