Deep peroneal sensory nerve. Standardization in nerve conduction study.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 2383381.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Ankle or foot pain may be due to various clinical conditions. Injury or entrapment of the deep peroneal sensory nerve is part of the differential diagnosis; however, no technique studying the deep peroneal sensory conduction velocity has been described. We describe a technique that is simple and reproducible with averaging. We electrophysiologically studied the deep peroneal sensory nerve in 40 neurologically healthy adult subjects. The latency to onset of the sensory action potential was 2.9 +/- 0.4 ms (range = 2.1-3.6 ms). The latency to the peak of the sensory action potential was 3.6 +/- 0.4 ms (range = 2.7-4.2 ms). The conduction velocity was 42 +/- 5 m/s (range = 33-53 m/s). The amplitude was 3.4 +/- 1.2 microV (range = 1.6-6.6 microV). We conclude that the deep peroneal sensory nerve is readily accessible for electrophysiologic evaluation. It may be of value in diagnosing deep peroneal nerve pathology.
Medical subject headings
- Electrodiagnosis
- Neural Conduction
- Peroneal Nerve