Effects of high positive end-expiratory pressure on haemodynamics and cerebral oxygenation during pneumoperitoneum in the Trendelenburg position.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 23841822.
- Also identified by DOI 10.1111/anae.12284.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We investigated the effects of 10 cmH2O positive end-expiratory pressure on cerebral haemodynamics and cerebral oxygenation in patients undergoing laparoscopic lower abdominal surgery in the 30° Trendelenburg position during desflurane anaesthesia. Twenty-six patients were enrolled in this study. After anaesthesia induction, pneumoperitoneum was applied in Trendelenburg position. Twenty minutes later, positive end-expiratory pressure was applied. There was no change in regional cerebral oxygen saturation (p = 0.376). Cerebral perfusion pressure decreased significantly over time (p < 0.001) and positive end-expiratory pressure caused a further decrease in cerebral perfusion pressure (p = 0.036). The application of 10 cmH2O positive end-expiratory pressure during pneumoperitoneum in the Trendelenburg position preserved regional cerebral oxygen saturation, but cerebral perfusion pressure decreased significantly due to its secondary haemodynamic effects.
Medical subject headings
- Cerebrovascular Circulation
- Head-Down Tilt
- Hemodynamics
- Pneumoperitoneum, Artificial
- Positive-Pressure Respiration