Effectiveness of an oxidized cellulose patch hemostatic agent in thyroid surgery: a prospective, randomized, controlled study.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 23870217.
- Also identified by DOI 10.1016/j.jamcollsurg.2013.03.022.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This single-blinded, prospective, randomized controlled trial compared the efficacy and safety of an oxidized cellulose patch (Surgicel [Johnson and Johnson]) with conventional procedures for achieving hemostasis in thyroid surgery. The study included 190 patients scheduled for thyroidectomy. Patients were randomized into 1 conventionally treated (ligatures and bipolar electrocautery) group (n = 92) and a second group, which additionally received Surgicel (n = 98). The groups were demographically and clinically matched and had similar wound drainage volumes and mean duration of surgery. Postoperative bleeding rate was greater in the Surgicel group, yet the difference didn't reach statistical significance (p = 0.054). There were no significant group differences in postoperative wound infection, seroma, hypocalcemia, or recurrent laryngeal nerve palsy. Time to drain removal and length of hospital stay were significantly shorter in the conventional group (p < 0.001). Routine use of an oxidized cellulose hemostatic agent has no advantage over conventional hemostasis and is potentially harmful in thyroid surgery.
Medical subject headings
- Blood Loss, Surgical
- Cellulose, Oxidized
- Hemostasis, Surgical
- Hemostatics
- Postoperative Hemorrhage
- Thyroidectomy