Examining clinical decision support integrity: is clinician self-reported data entry accurate?
Where this comes from
- Record sourced from PubMed, PMID 23886922.
- Also identified by DOI 10.1136/amiajnl-2013-001617 and PMC identifier 3912709.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The aim of this study was to assess the accuracy of clinician-entered data in imaging clinical decision support (CDS). We used CDS-guided CT angiography (CTA) for pulmonary embolus (PE) in the emergency department as a case example because it required clinician entry of d-dimer results which could be unambiguously compared with actual laboratory values. Of 1296 patients with CTA orders for suspected PE during 2011, 1175 (90.7%) had accurate d-dimer values entered. In 55 orders (4.2%), incorrectly entered data shielded clinicians from intrusive computer alerts, resulting in potential CTA overuse. Remaining data entry errors did not affect user workflow. We found no missed PEs in our cohort. The majority of data entered by clinicians into imaging CDS are accurate. A small proportion may be intentionally erroneous to avoid intrusive computer alerts. Quality improvement methods, including academic detailing and improved integration between electronic medical record and CDS to minimize redundant data entry, may be necessary to optimize adoption of evidence presented through CDS.
Medical subject headings
- Decision Support Systems, Clinical
- Diagnostic Imaging
- Information Storage and Retrieval
- Medical Order Entry Systems
- Pulmonary Embolism