Monorail system for percutaneous repositioning of the Greenfield vena caval filter.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 2389052.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The authors describe a technique for removing or repositioning a malpositioned Greenfield inferior vena caval filter. A "monorail" system was used, in which a wire was passed from the femoral vein through the apical hole in the filter and out the internal jugular vein; the wire was held taut from above and below and thus facilitated repositioning or removal of the filter. The technique was used successfully in two cases.
Medical subject headings
- Filtration
- Pulmonary Embolism
- Vena Cava, Inferior