Endovascular repair of aortic arch false aneurysm with branched endograft.

Schiro, Andrew; Kuhan, Ganesh; Pichel, Adam; Farquharson, Finn; Murray, David; Serracino-Inglott, Ferdinand · J Vasc Surg · 2014

case_report · Level V

Where this comes from

Abstract

This case report describes the use of a customized branched device for the treatment of a distal anastomotic false aneurysm in an ascending to descending interposition graft in a 34-year-old Jehovah's Witness with congenital aortic arch interruption. A single branched customized stent graft device was used to successfully exclude the false aneurysm. The procedure was challenging due to the abnormal congenital anatomy. The planning, operative technique, and successful execution are described in this case report.

Medical subject headings