The effects of freezing or freeze-drying on the biomechanical properties of the canine intervertebral disc.

Flynn, J; Rudert, M J; Olson, E; Baratz, M; Hanley, E · Spine (Phila Pa 1976) · 1990

biomechanical · Level V

Where this comes from

Abstract

The transplantation of spinal allografts to correct defects that include disc, body, or segments of both is currently under experimental investigation. A method of graft preservation that will least compromise the biomechanical integrity of the bodies or discs is required. Using a five-mode biomechanical analysis, the authors compared the change in stiffness of ten preserved canine spines. The freeze-dried specimens lost a significantly greater amount of stiffness in compression, flexion, extension, and torsion than did the frozen specimens. Therefore, from a biomechanical viewpoint, deep-freezing is superior to freeze-drying for spinal allograft preservation.

Medical subject headings