Needle biopsy of renal allografts: comparison of two techniques.

Bogan, M L; Kopecky, K K; Kraft, J L; Holladay, A O; Filo, R S; Leapman, S B; Thomalla, J V · Radiology · 1990

retrospective_cohort · Level III

Where this comes from

Abstract

Two techniques for renal allograft biopsy were retrospectively evaluated to compare relative safety and efficacy. After ultrasound (US) localization of the kidney and biopsy with a hand-held 14-gauge cutting needle, an adequate specimen was obtained in 74 of 77 cases (96%). Major complications occurred in six of these 77 cases (8%). One hundred four biopsies were performed by using a smaller 18-gauge cutting needle with a spring-loaded biopsy "gun" and real-time US guidance. With this newer technique, specimens adequate for diagnosis were obtained in 99 biopsies (95%). There was a single major complication with this technique (1%). The 18-gauge needle with real-time US guidance yields comparably adequate specimens with a lower frequency of complications.