A novel radiographic index for the diagnosis of posterior acromioclavicular joint dislocations.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 24124199.
- Also identified by DOI 10.1177/0363546513506849.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Posterior acromioclavicular (AC) joint dislocations are frequently misclassified because posterior translation of the clavicle is difficult to evaluate in Zanca radiograph views. A novel radiographic index was used in this study to accurately diagnose posterior dislocations of the AC joint. This novel index has a high degree of accuracy for the diagnosis of posterior AC joint dislocations. Cohort study (diagnosis); Level of evidence, 2. This was an analytic, descriptive study of 150 patients with different grades of AC injuries according to the Rockwood classification (30 patients for each grade of injury: I, II, III, IV, and V). The diagnosis of an AC injury was made both clinically and radiographically by using comparative Zanca and axillary views. Two measurements were performed in Zanca views: the coracoclavicular distance and the AC width distance. A width index was calculated for each patient. The Student t test, Bonferroni test, logistic regression, linear regression, and receiver operating characteristic (ROC) curves were used for statistical analysis. Forty cases were impartially selected to obtain a κ concordance value. The average value of the AC width index per group (according to the Rockwood classification) was as follows: type I, 2.1% (range, -12% to 25%); type II, 4.2% (range, -19% to 29%); type III, 19.1% (range, -59% to 91%); type IV, 110.3% (range, 47% to 181%); and type V, -3.8% (range, -71% to 62%). There was a significant difference between the average width index in the patients with type IV injuries and those in the remaining groups (P < .05). The ROC curve showed that a width index of 60% has a sensitivity of 95.7% and specificity of 97.5%, with a positive predictive value of 96.7% and negative predictive value of 95.6% to predict a type IV injury. Intraobserver reliability was rated as substantial agreement for each of 3 observers; the interobserver reliability of the 3 independent raters was almost perfect. An AC width index of ≥60% is highly accurate for the diagnosis of a posterior AC joint dislocation, with high intraobserver and interobserver concordance.
Medical subject headings
- Acromioclavicular Joint
- Shoulder Dislocation
Anatomy
- clavicle
- shoulder