Prognostic utility of 90Y radioembolization dosimetry based on fusion 99mTc-macroaggregated albumin-99mTc-sulfur colloid SPECT.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 24144563.
- Also identified by DOI 10.2967/jnumed.113.123257.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Planning hepatic (90)Y radioembolization activity requires balancing toxicity with efficacy. We developed a dual-tracer SPECT fusion imaging protocol that merges data on radioactivity distribution with physiologic liver mapping. Twenty-five patients with colorectal carcinoma and bilobar liver metastases received whole-liver radioembolization with resin microspheres prescribed as per convention (mean administered activity, 1.69 GBq). As part of standard treatment planning, all patients underwent SPECT imaging after intraarterial injection of 37 MBq of (99m)Tc-macroaggregated albumin ((99m)Tc-MAA) to simulate subsequent (90)Y distribution. Immediately afterward, patients received 185 MBq of labeled sulfur colloid ((99m)Tc-SC) intravenously as a biomarker for normal hepatic reticuloendothelial function and SPECT was repeated. The SPECT images were coregistered and fused. A region-based method was used to predict the (90)Y radiation absorbed dose to functional liver tissue (DFL) by calculation of (99m)Tc-MAA activity in regions with (99m)Tc-SC uptake. Similarly, the absorbed dose to tumor (DT) was predicted by calculation of (99m)Tc-MAA activity in voxels without (99m)Tc-SC uptake. Laboratory data and radiographic response were measured for 3 mo, and the survival of patients was recorded. SPECT-based DT and DFL were correlated with parameters of toxicity and efficacy. Toxicity, as measured by increase in serum liver enzymes, correlated significantly with SPECT-based calculation of DFL at all time points (P < 0.05) (mean DFL, 27.9 Gy). Broad biochemical toxicity (>50% increase in all liver enzymes) occurred at a DFL of 24.5 Gy and above. In addition, in uni- and multivariate analysis, SPECT-based calculation of DT (mean DT, 44.2 Gy) correlated with radiographic response (P < 0.001), decrease in serum carcinoembryonic antigen (P < 0.05), and overall survival (P < 0.01). The cutoff value of DT for prediction of 1-y survival was 55 Gy (area under the receiver-operating-characteristic curve = 0.86; P < 0.01). Patients who received a DT of more than 55 Gy had a median survival of 32.8 mo, compared with 7.2 mo in patients who received less (P < 0.05). Dual-tracer (99m)Tc-MAA-(99m)Tc-SC fusion SPECT offers a physiology-based imaging tool with significant prognostic power that may lead to improved personalized activity planning.
Medical subject headings
- Embolization, Therapeutic
- Image Processing, Computer-Assisted
- Liver Neoplasms
- Technetium Tc 99m Aggregated Albumin
- Technetium Tc 99m Sulfur Colloid
- Tomography, Emission-Computed, Single-Photon