High-performance, low-voltage electroosmotic pumps with molecularly thin silicon nanomembranes.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 24167263.
- Also identified by DOI 10.1073/pnas.1308109110 and PMC identifier 3831982.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We have developed electroosmotic pumps (EOPs) fabricated from 15-nm-thick porous nanocrystalline silicon (pnc-Si) membranes. Ultrathin pnc-Si membranes enable high electroosmotic flow per unit voltage. We demonstrate that electroosmosis theory compares well with the observed pnc-Si flow rates. We attribute the high flow rates to high electrical fields present across the 15-nm span of the membrane. Surface modifications, such as plasma oxidation or silanization, can influence the electroosmotic flow rates through pnc-Si membranes by alteration of the zeta potential of the material. A prototype EOP that uses pnc-Si membranes and Ag/AgCl electrodes was shown to pump microliter per minute-range flow through a 0.5-mm-diameter capillary tubing with as low as 250 mV of applied voltage. This silicon-based platform enables straightforward integration of low-voltage, on-chip EOPs into portable microfluidic devices with low back pressures.
Medical subject headings
- Lab-On-A-Chip Devices
- Membranes, Artificial
- Microfluidics
- Nanostructures
- Osmotic Pressure
- Silicon