Tapered fluted modular titanium stems in the management of Vancouver B2 and B3 peri-prosthetic fractures.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 24187345.
- Also identified by DOI 10.1302/0301-620X.95B11.32898.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Tapered, fluted, modular, titanium stems are increasingly popular in the operative management of Vancouver B2 and selected B3 peri-prosthetic femoral fractures. We have reviewed the results at our institution looking at stem survival and clinical outcomes and compared this with reported outcomes in the literature. Stem survival at a mean of 54 months was 96% in our series and 97% for combined published cases. Review of radiology showed maintenance or improvement of bone stock in 89% of cases with high rates of femoral union. Favourable clinical outcome scores have reported by several authors. No difference in survival or clinical scores was observed between B2 and B3 fractures. Tapered stems are a useful option in revision for femoral fracture across the spectrum of femoral bone deficiency.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Femoral Fractures
- Fracture Fixation, Internal
- Hip Prosthesis
- Periprosthetic Fractures
- Prosthesis Design
Anatomy
- femur
- hip